L6472
Programming manual
OC_SD
1
0
Table 27. Overcurrent event
Overcurrent event
Bridges shut down
Bridges do not shut down
The POW_SR bits set the slew rate value of the power bridge output:
Table 28. Programmable power bridge output slew rate values
POW_SR [1 … 0]
Output slew rate (1) [V/s](1)
0
0
320
0
1
75
1
0
110
1
1
270
1. See SRout_r and SRout_f parameters in Table 5 on page 11 for details.
The TQREG bit sets if the torque regulation (see Section 7.4 on page 37) is performed
through ADCIN voltage (external) or the TVAL_HOLD, TVAL_ACC, TVAL_DEC and
TVAL_RUN registers (internal):
Table 29. External torque regulation enable
TQREG
External torque regulation enable
0
Internal registers
1
ADC input
The TSW parameter is used by the current control system and it sets the target switching
period.
Table 30. Switching period
TSW [4 … 0]
Switching period
0
0
0
0
0
4 µs (250 kHz)
0
0
0
0
1
0
0
0
1
0
4 µs (250 kHz)
8 µs (125 kHz)
1
1
1
1
1
124 µs (8 kHz)
Any attempt to write the CONFIG register when the motor is running causes the command
to be ignored and the NOTPERF_CMD flag to rise (see Section 9.1.19).