Programming manual
0
0
0
0
Table 14. Minimum ON time
0
0
0
0
0
0
0
0
0
1
L6474
Time
0.5 µs
1 µs
9.1.7
1
1
1
1
1
1
0
1
1
1
1
1
1
1
63.5 µs
64 µs
Any attempt to write to the register when the outputs are enabled causes the command to
be ignored and the NOTPERF_CMD to rise (see Section 9.1.13 on page 41).
TOFF_MIN
The TOFF_MIN register contains the minimum OFF time value used by the current control
system (see Section 7.1 on page 27 for details).This parameter imposes the OFF time of the
current control system only if its value is greater than the TSW one.
The available range for both parameters is from 0.5 µs to 64 µs.
Table 15. Minimum OFF time
0
0
0
0
0
0
0
0
0
0
0
0
0
1
Time
0.5 µs
1 µs
1
1
1
1
1
1
0
1
1
1
1
1
1
1
63.5 µs
64 µs
Any attempt to write to the register when the outputs are enabled causes the command to
be ignored and the NOTPERF_CMD to rise (see Section 9.1.13).
36/53
DocID022529 Rev 4