LHF64P01
18
1.2.3 DC Characteristics
Symbol
Parameter
ILI
Input Load Current
ILO
Output Leakage Current
ICCS
VCC Standby Current
VCC=2.7V-3.6V
Notes Min. Typ.
1
-1
Max.
+1
1
-10
+10
1, 2, 8
50 120
0.71 2
ICCAS VCC Automatic Power Savings Current 1, 2, 5
ICCD VCC Reset Current
1
1, 2
Average VCC Page 4 word/ 8 byte
Mode Read Current read
ICCR
1, 2
50 120
50 120
15
20
24
29
Average VCC Read 1 word/ 1 byte
Current
read
1, 2
ICCW
1, 2, 6
VCC (Page Buffer) Program, Set Block
Lock Bit Current
1, 2, 6
40
50
35
60
40
70
Unit
Test Conditions
µA VCC=VCCMax.,
VCCQ=VCCQMax.,
µA VIN/VOUT=VCCQ or
GND
CMOS Inputs,
VCC=VCCMax.,
µA VCCQ=VCCQMax.,
Device is disabled
(refer to Table 2),
RP#=VCCQ±0.2V
TTL Inputs,
VCC=VCCMax.,
mA VCCQ=VCCQMax.,
Device is disabled
(refer to Table 2),
RP#=VIH
CMOS Inputs,
VCC=VCCMax.,
µA VCCQ=VCCQMax.,
Device is enabled
(refer to Table 2)
µA
RP#=GND±0.2V
IOUT (STS)=0mA
CMOS Inputs,
VCC=VCCMax.,
mA VCCQ=VCCQMax.,
Device is enabled
(refer to Table 2),
f=5MHz, IOUT=0mA
CMOS Inputs,
VCC=VCCMax.,
mA VCCQ=VCCQMax.,
Device is enabled
(refer to Table 2),
f=33MHz, IOUT=0mA
CMOS Inputs,
VCC=VCCMax.,
mA VCCQ=VCCQMax.,
Device is enabled
(refer to Table 2),
f=5MHz, IOUT=0mA
CMOS Inputs,
mA VPEN=VPENH
TTL Inputs,
mA VPEN=VPENH
Rev. 0.06