SHARP
SPEC No.
LC99908
MODEL No.
LM057QCTT03
PAGE
21 I
6) Operating life
The operating life time is 25 000 hours or more at 6 mArms, 25 + 1°C
(Operating life with CXA-MlOL or quivalent.)
The inverter should meet the following conditions to keep the specified life time of used lamp;
-Sine wave form, symmetric in positive and negative, no ripple or spike pulse
-Output frequency range: 4Oh-80 kH2
Check well that CCFT works properly with enough aging time.
The operating life time is defined as the time either of following conditions are met.
-When the luminance or amount of light output is decreased to 60 % of the initials value.
-When the kick-off voltage reaches Maximum value in Table 11.
(NOTE) Ratings are defined as the average brightness inside the viewing area specified in Fig.11.
60
180
dots
I
I
I
80
160
240
dots
(l-5)
Activation
Finger
-
0.5
N
Stylus
-
0.5
N
Surface hardness
Optical clarity
2H
-
-
-