LND317
TYPICAL APPLICATIONS
D1
VIN
VIN
VOUT
VOUT
VIN
LND317
D2
Adjust
R1
240
R2
+ C2
C1
10 µF
D1 protects against C1
D2 protects against C2
Regulator with Protection Diodes
VIN
VOUT
LND317
Adjust
R1
IOUT
IAdj
( ) IOUT =
VREF
R1
+ IAdj
= 1.25 V
R1
10 mA <=IOUT<= 1.5 A
Current Regulator
VIN
VIN
VOUT
24
LND317
Adjust
50 mA Constant Current Battery Charger
• Linear Dimensions, Inc. • 445 East Ohio Street, Chicago IL 60611 USA • tel 312.321.1810 • fax 312.321.1830 • www.lineardimensions.com •