LinkSwitch-HP
Parameter
Conditions
Symbol
SOURCE = 0 V; TJ = -40 to 125 °C
Min
Typ
(Unless Otherwise Specified)
Circuit Protection (cont.)
Minimum Switch
ON-Time
Output
TON(MIN)
ON-State Resistance
RDS(ON)
OFF-State Drain
Leakage Current
IDSS
Breakdown Voltage
BVDSS
DRAIN Supply Voltage
t + t LEB(MAX) ILD(MAX)
TJ = +25 °C
325
LNK6xx3
ID = 100 mA
LNK6xx4
ID = 150 mA
LNK6xx5
ID = 200 mA
LNK6xx6
ID = 300 mA
LNK6xx7
ID = 400 mA
LNK6xx8
ID = 500 mA
LNK6xx9
ID = 600 mA
VPD =
Floating
TJ = +25 °C
TJ = +100 °C
TJ = +25 °C
TJ = +100 °C
TJ = +25 °C
TJ = +100 °C
TJ = +25 °C
TJ = +100 °C
TJ = +25 °C
TJ = +100 °C
TJ = +25 °C
TJ = +100 °C
TJ = +25 °C
TJ = +100 °C
VDS = 560 V, TJ = 125 °C
VDS = 325 V, TJ = 100 °C
LNK677x, VPD = Floating,
TJ = +25 °C
725
LNK666x/LNK676x, VPD = Floating,
TJ = +25 °C
650
50
400
6.9
10.5
4.6
7.0
3.5
5.4
2.3
3.6
1.8
2.7
1.5
2.3
1.3
2.0
Rise Time
tR
Measured in a typical flyback
100
Fall Time
TF
Converter application
50
NOTES:
A. Parameter not tested over specified temperature range. Guaranteed by design and characterization.
B. Average device switching frequency below 1 kHz.
Max
500
7.97
12.08
5.30
8.09
4.03
6.21
2.65
4.14
2.07
3.11
1.95
2.90
1.70
2.60
470
10
Units
ns
W
mA
V
V
ns
16
Rev. E 06/15