Qdatasheet_Logo
Integrated circuits, Transistor, Semiconductors Search and Datasheet PDF Download Site

LPC47M112 View Datasheet(PDF) - SMSC -> Microchip

Part Name
Description
MFG CO.
'LPC47M112' PDF : 204 Pages View PDF
Enhanced Super I/O Controller with LPC Interface
Datasheet
DATA ADDRESS
SK BIT MARK TYPE
VALUE ENCOUNTERED
1 Normal Data
1 Deleted Data
RESULTS
SECTOR
READ?
Yes
No
CM BIT OF
ST2 SET?
No
Yes
DESCRIPTION OF
RESULTS
searched for.
Normal
termination.
Normal
termination.
Sector not read
("skipped").
Read Deleted Data
This command is the same as the Read Data command, only it operates on sectors that contain a Deleted Data Address
Mark at the beginning of a Data Field.
Table 21 describes the effect of the SK bit on the Read Deleted Data command execution and results.
Except where noted in Table 21, the C or R value of the sector address is automatically incremented (see Table 22).
Table 21 - Skip Bit vs. Read Deleted Data Command
SK BIT
VALUE
DATA ADDRESS
MARK TYPE
ENCOUNTERED
0 Normal Data
0 Deleted Data
1 Normal Data
1 Deleted Data
RESULTS
SECTOR
READ?
Yes
Yes
No
Yes
CM BIT OF
ST2 SET?
Yes
No
Yes
No
DESCRIPTION OF
RESULTS
Address not
incremented. Next
sector not
searched for.
Normal
termination.
Normal
termination.
Sector not read
("skipped").
Normal
termination.
Read A Track
This command is similar to the Read Data command except that the entire data field is read continuously from each of
the sectors of a track. Immediately after encountering a pulse on the nINDEX pin, the FDC starts to read all data fields
on the track as continuous blocks of data without regard to logical sector numbers. If the FDC finds an error in the ID or
DATA CRC check bytes, it continues to read data from the track and sets the appropriate error bits at the end of the
command. The FDC compares the ID information read from each sector with the specified value in the command and
sets the ND flag of Status Register 1 to a “1” if there no comparison. Multi-track or skip operations are not allowed with
this command. The MT and SK bits (bits D7 and D5 of the first command byte respectively) should always be set to "0".
This command terminates when the EOT specified number of sectors has not been read. If the FDC does not find an ID
Address Mark on the diskette after the second occurrence of a pulse on the INDEX pin, then it sets the IC code in Status
Register 0 to "01" (abnormal termination), sets the MA bit in Status Register 1 to "1", and terminates the command.
SMSC DS – LPC47M112
Page 52
DATASHEET
Rev. 02-16-07
Share Link: GO URL