LTC1864/LTC1865
TIMING CHARACTERISTICS The ● denotes specifications which apply over the full operating temperature
range, otherwise specifications are TA = 25°C. VCC = 5V, VREF = 5V, fSCK = fSCK(MAX) as defined in Recommended Operating Conditions,
unless otherwise noted.
LTC1864/LTC1865
SYMBOL PARAMETER
CONDITIONS
MIN
TYP MAX UNITS
tCONV
Conversion Time (See Figure 1)
fSMPL(MAX) Maximum Sampling Frequency
tdDO
Delay Time, SCK↓ to SDO Data Valid
tdis
Delay Time, CONV↑ to SDO Hi-Z
H-Grade
H-Grade
CLOAD = 20pF
CLOAD = 20pF
CLOAD = 20pF, H-Grade
H-Grade
●
●
●
250
●
234
●
●
●
●
2.75
3.2
μs
2.75
3.3
μs
kHz
kHz
15
20
ns
25
ns
30
ns
30
60
ns
30
65
ns
ten
Delay Time, CONV↓ to SDO Enabled
CLOAD = 20pF
●
CLOAD = 20pF, H-Grade
●
30
60
ns
30
65
ns
thDO
Time Output Data Remains Valid After SCK↓ CLOAD = 20pF
●
5
10
ns
tr
SDO Rise Time
CLOAD = 20pF
8
ns
tf
SDO Fall Time
CLOAD = 20pF
4
ns
Note 1: Stresses beyond those listed under Absolute Maximum Ratings
may cause permanent damage to the device. Exposure to any Absolute
Maximum Rating condition for extended periods may affect device
reliability and lifetime.
Note 2: All voltage values are with respect to GND.
Note 3: Integral nonlinearity is defined as deviation of a code from a
straight line passing through the actual endpoints of the transfer curve.
The deviation is measured from the center of the quantization band.
Note 4: Channel leakage current is measured while the part is in sample
mode.
Note 5: Guaranteed by design, not subject to test.
18645fb
7