LTC2941
PIN FUNCTIONS
SENSE+ (Pin 1): Positive Current Sense Input and Power
Supply. Connect to the load/charger side of the sense
resistor. VSENSE+ operating range is 2.7V to 5.5V.
GND (Pin 2, Exposed Pad Pin 7): Device Ground. Connect
directly to the negative battery terminal. Exposed pad may
be left open or connected to device ground.
SCL (Pin 3): Serial Bus Clock Input.
SDA (Pin 4): Serial Bus Data Input and Output.
AL/CC (Pin 5): Alert Output or Charge Complete Input.
Configured either as an SMBus alert output or charge
complete input by control register bits B[2:1]. At power-up,
the pin defaults to alert mode conforming to the SMBus
alert response protocol. It behaves as an open-drain logic
output that pulls to GND when a value in the threshold
registers is exceeded.
When configured as a charge complete input, connect
to the charge complete output from the battery charger
circuit. A high level at CC sets the value of the accumulated
charge (registers C, D) to FFFFh.
SENSE– (Pin 6): Negative Current Sense Input. Connect
SENSE– to the positive battery terminal side of the sense
resistor. The voltage between SENSE– and SENSE+ must
remain within ±50mV in normal operation.