LTC2978A
PMBus Command Description
STATUS_INPUT
The STATUS_INPUT command returns the summary of the VIN faults or warnings which have occurred, as shown in
the following table:
STATUS_INPUT Data Contents
BIT(S) SYMBOL
b[7] Status_input_ov_fault
b[6] Status_input_ov_warn
b[5] Status_input_uv_warn
b[4] Status_input_uv_fault
b[3] Status_input_off
b[2] IIN overcurrent fault
b[1] IIN overcurrent warn
b[0] PIN overpower warn
OPERATION
VIN Overvoltage fault
VIN Overvoltage warning
VIN Undervoltage warning
VIN Undervoltage fault
Unit is off for insufficient input voltage.
Not supported. Always returns 0.
Not supported. Always returns 0.
Not supported. Always returns 0.
STATUS_TEMPERATURE
The STATUS_TEMPERATURE command returns the summary of the temperature faults or warnings which have oc-
curred, as shown in the following table:
STATUS_TEMPERATURE Data Contents
Bit(s) Symbol
Operation
b[7] Status_temperature_ot_fault Overtemperature fault.
b[6] Status_temperature_ot_warn Overtemperature warning.
b[5] Status_temperature_ut_warn Undertemperature warning.
b[4] Status_temperature_ut_fault Undertemperature fault.
b[3] Reserved
Reserved. Always returns 0.
b[2] Reserved
Reserved. Always returns 0.
b[1] Reserved
Reserved. Always returns 0.
b[0] Reserved
Reserved. Always returns 0.
2978af
40
For more information www.linear.com/LTC2978A