Qdatasheet_Logo
Integrated circuits, Transistor, Semiconductors Search and Datasheet PDF Download Site

LTC2978C View Datasheet(PDF) - Linear Technology

Part Name
Description
MFG CO.
'LTC2978C' PDF : 64 Pages View PDF
LTC2978
PMBus Command Description
MFR_CONFIG_LTC2978 Data Contents
BIT(S) SYMBOL
OPERATION
b[0] Mfr_config_dac_pol
DAC output polarity.
0: Encodes negative (inverting) DC/DC converter trim input.
1: Encodes positive (noninverting) DC/DC converter trim input.
MFR_CONFIG_ALL_LTC2978
This command is used to configure parameters that are common to all channels on the IC. They may be set or reviewed
from any PAGE setting.
MFR_CONFIG_ALL_LTC2978 Data Contents
BIT(S)
b[7]
b[6]
b[5]
b[4]
b[3]
b[2]
b[1]
b[0]
SYMBOL
Mfr_config_all_fault_log_enable
Mfr_config_all_vin_on_clr_
faults_en
Mfr_config_all_control1_pol
Mfr_config_all_control0_pol
Mfr_config_all_vin_share_
enable
Mfr_config_all_pec_en
Mfr_config_all_longer_pmbus_
timeout
Mfr_config_all_vinen_wpu_dis
OPERATION
Enable fault logging to EEPROM in response to Fault.
0: Fault logging to EEPROM is disabled
1: Fault logging to EEPROM is enabled
Allow VIN rising above VIN_ON to clear all latched faults
0: VIN_ON clear faults feature is disabled
1: VIN_ON clear faults feature is enabled
Selects active polarity of CONTROL1 pin.
0: Active low (pull pin low to start unit)
1: Active high (pull pin high to start unit)
Selects active polarity of CONTROL0 pin.
0: Active low (pull pin low to start unit)
1: Active high (pull pin high to start unit)
Allow this unit to hold SHARE_CLK pin low when VIN has not risen above VIN_ON or has fallen below VIN_
OFF. When enabled, this unit will also turn all channels off in response to share-clock being held low.
0: SHARE_CLK inhibit is disabled
1: SHARE_CLK inhibit is enabled
PMBus packet error checking enable.
0: PEC is accepted but not required
1: PEC is required
Increase PMBus timeout internal by a factor of 8. Recommended for fault logging.
0: PMBus timeout is not multiplied by a factor of 8
1: PMBus timeout is multiplied by a factor of 8
VIN_EN charge-pumped, current-limited pull-up disable.
0: Use weak current-limited pull-up on VIN_EN after power-up, as long as no faults have forced VIN_EN off.
1: Disable weak pull-up. VIN_EN driver is three-stated after power-up as long as no faults have forced VIN_EN
off.
For more information www.linear.com/LTC2978