Overview
Table 1. LTC2983 Error Contribution and Peak Noise Errors
SENSOR TYPE
TEMPERATURE RANGE
Type K Thermocouple
–200°C to 0°C
0°C to 1372°C
Type J Thermocouple
–210°C to 0°C
0°C to 1200°C
Type E Thermocouple
–200°C to 0°C
0°C to 1000°C
Type N Thermocouple
–200°C to 0°C
0°C to 1300°C
Type R Thermocouple
0°C to 1768°C
Type S Thermocouple
0°C to 1768°C
Type B Thermocouple
400°C to 1820°C
Type T Thermocouple
–250°C to 0°C
0°C to 400°C
External Diode (2 Reading)
–40°C to 85°C
External Diode (3 Reading)
–40°C to 85°C
Platinum RTD - PT-10, RSENSE = 1kΩ
Platinum RTD - PT-100, RSENSE = 2kΩ
Platinum RTD - PT-500, RSENSE = 2kΩ
Platinum RTD - PT-1000, RSENSE = 2kΩ
–200°C to 800°C
–200°C to 800°C
–200°C to 800°C
–200°C to 800°C
Thermistor, RSENSE = 10kΩ
–40°C to 85°C
ERROR CONTRIBUTION
±(Temperature • 0.23% + 0.05)°C
±(Temperature • 0.12% + 0.05)°C
±(Temperature • 0.23% + 0.05)°C
±(Temperature • 0.10% + 0.05)°C
±(Temperature • 0.18% + 0.05)°C
±(Temperature • 0.10% + 0.05)°C
±(Temperature • 0.27% + 0.08)°C
±(Temperature • 0.10% + 0.08)°C
±(Temperature • 0.10% + 0.4)°C
±(Temperature • 0.10% + 0.4)°C
±(Temperature • 0.10%)°C
±(Temperature • 0.15% + 0.05)°C
±(Temperature • 0.10% + 0.05)°C
±0.25°C
±0.25°C
±0.1°C
±0.1°C
±0.1°C
±0.1°C
±0.1°C
PEAK-TO-PEAK NOISE
±0.08°C
±0.07°C
±0.06°C
±0.13°C
±0.62°C
±0.62°C
±0.83°C
±0.09°C
±0.05°C
±0.2°C
±0.05°C
±0.05°C
±0.02°C
±0.01°C
±0.01°C
Table 1 shows the estimated system accuracy and noise
associated with specific temperature sensing devices.
System accuracy and peak-to-peak noise include the effects
of the ADC, internal amplifiers, excitation current sources,
and integrated reference for I-grade parts. Accuracy
and noise are the worst-case errors calculated from the
guaranteed maximum ADC and reference specifications.
Peak-to-peak noise values are calculated at 0°C (except
type B was calculated at 400°C) and diode measurements
use AVG = ON mode.
Thermocouple errors do not include the errors associated
with the cold junction measurement. Errors associated
with a specific cold junction sensor within the operating
temperature range can be combined with the errors for a
given thermocouple for total temperature measurement
accuracy.