OPERATION
Table 8. Input Connector Priority Swap
INPUT CONNECTOR PRIORITY SWAP
SUB ADDRESS 0x01
PRIORITY
DIRECTION
Write and Readback
PRIORITY
D7 D6 D5 D4 D3 D2
Wall Input
Prioritized*
0
USB Input
Prioritized
1
*Default setting
REG1
D1 D0
Table 9. Battery Charger Safety Timer
BATTERY CHARGER SAFETY TIMER
SUB ADDRESS 0x01
TIMER[1:0]
DIRECTION
Write and Readback
TIMER[1:0]
D7 D6 D5 D4 D3 D2
1 Hr*
00
4 Hr or C/x
Indication
01
0.25 Hr
10
0.50 Hr
11
*Default setting.
REG1
D1 D0
LTC4156
Table 10. Battery Charger Current Limit
BATTERY CHARGER CURRENT LIMIT
SUB ADDRESS
0x02
ICHARGE[3.0]
DIRECTION
Write and Readback
FULL-SCALE VPROG
CURRENT SERVO
(%)
(V) D7 D6 D5 D4 D3 D2
Charger
Disabled
0.000
0
0
0
0
12.50 0.150 0 0 0 1
18.75 0.225 0 0 1 0
25.00 0.300 0 0 1 1
31.25 0.375 0 1 0 0
37.50 0.450 0 1 0 1
43.75 0.525 0 1 1 0
50.00 0.600 0 1 1 1
56.25 0.675 1 0 0 0
62.50 0.750 1 0 0 1
68.75 0.825 1 0 1 0
75.00 0.900 1 0 1 1
81.25 0.975 1 1 0 0
87.50 1.050 1 1 0 1
93.75 1.125 1 1 1 0
100.00* 1.200* 1 1 1 1
*Default setting.
REG2
D1 D0
4156f
35