DC and AC parameters
M24256-BW M24256-BR M24256-BF M24256-DR M24256-DF
8
DC and AC parameters
This section summarizes the operating and measurement conditions, and the DC and AC
characteristics of the device.
Symbol
VCC
TA
fC
Table 7. Operating conditions (voltage range W)
Parameter
Min.
Max.
Supply voltage
2.5
5.5
Ambient operating temperature
–40
85
Operating clock frequency
-
1
Unit
V
°C
MHz
Symbol
VCC
TA
fC
Table 8. Operating conditions (voltage range R)
Parameter
Min.
Max.
Supply voltage
Ambient operating temperature
1.8
5.5
–40
85
Operating clock frequency
-
1
Unit
V
°C
MHz
Table 9. Operating conditions (voltage range F)
Symbol
Parameter
Min.
Max.
VCC Supply voltage
TA
Ambient operating temperature
fC
Operating clock frequency
1.7
5.5
–40
85
-
1
Unit
V
°C
MHz
Symbol
Cbus
-
-
-
Table 10. AC measurement conditions
Parameter
Min.
Max.
Load capacitance
-
100
SCL input rise/fall time, SDA input fall time
Input levels
Input and output timing reference levels
-
50
0.2 VCC to 0.8 VCC
0.3 VCC to 0.7 VCC
Figure 11. AC measurement I/O waveform
)NPUT VOLTAGE LEVELS
6##
6##
)NPUT AND OUTPUT
4IMING REFERENCE LEVELS
6##
6##
Unit
pF
ns
V
V
-36
24/47
DS1766 Rev 34