M24C16-125 M24C08-125 M24C04-125 M24C02-125
DC and AC parameters
Table 8. DC characteristics
Symbol
Parameter
Test condition
(in addition to those in Table 5)
Min.
Max. Unit
ILI
Input leakage current (SCL,
SDA, E0, E1,and E2)
VIN = VSS or VCC, device in
Standby mode
-
± 2 µA
ILO Output leakage current
ICC Supply current
ICC1 Standby supply current
VIL
Input low voltage (SDA,
SCL, WC)
SDA in Hi-Z, external voltage
applied on SDA: VSS or VCC
-
VCC = 5 V, fC= 400 kHz
(rise/fall time < 50 ns)
-
VCC = 2.5 V, fC = 400 kHz
(rise/fall time < 50 ns)
-
Device not selected(1), VIN = VSS
or VCC, VCC = 5 V
-
Device not selected(1), VIN = VSS
or VCC, VCC = 2.5 V
-
± 2 µA
3 mA
3 mA
5
µA
2
µA
–0.45 0.3 VCC V
VIH
Input high voltage (SDA,
SCL, WC)
0.7 VCC VCC+1 V
VOL Output low voltage
IOL = 2.1 mA when VCC = 2.5 V or
IOL = 3 mA when VCC = 5.5 V
-
0.4 V
1. The device is not selected after a power-up, after a read command (after the Stop condition), or after the
completion of the internal write cycle tW (tW is triggered by the correct decoding of a write command).
Doc ID 022564 Rev 1
21/30