M25P80
DC and AC parameters
Table 14. DC characteristics
Symbol
Parameter
ILI Input leakage current
ILO Output leakage current
ICC1 Standby current
ICC2 Deep Power-down current
ICC3 Operating current (READ)
ICC4 Operating current (PP)
ICC5 Operating current (WRSR)
ICC6 Operating current (SE)
ICC7 Operating current (BE)
VIL Input low voltage
VIH Input high voltage
VOL Output low voltage
VOH Output high voltage
Grade 6
Grade 3
Grade 6
Grade 3
Test condition (in addition
to those in Table 10)
Min.
Max. Unit
±2
µA
±2
µA
S = VCC, VIN = VSS or VCC
50
µA
100
S = VCC, VIN = VSS or VCC
10
µA
100
C = 0.1VCC / 0.9.VCC at
75 MHz, Q = open
12
mA
C = 0.1VCC / 0.9.VCC at
20 MHz, Q = open
4
mA
S = VCC
S = VCC
S = VCC
S = VCC
IOL = 1.6 mA
IOH = –100 µA
15
mA
15
mA
15
mA
15
mA
–0.5
0.3VCC
V
0.7VCC VCC + 0.4 V
0.4
V
VCC – 0.2
V
39/52