DC and AC parameters
DC and AC parameters
This section summarizes the operating and measurement conditions, and the DC and AC
characteristics of the device. The parameters in the DC and AC Characteristic tables that
follow are derived from tests performed under the Measurement Conditions summarized in
the relevant tables. Designers should check that the operating conditions in their circuit
match the measurement conditions when relying on the quoted parameters.
Table 5. AC Measurement Conditions(1)
Input Rise and Fall Times
Input Pulse Voltages
Input and Output Timing Ref. Voltages
1. Note that Output Hi-Z is defined as the point where data is no longer driven.
Figure 5. AC Testing Input Output Waveform
≤20ns
0.4V to 2.4V
0.8 to 2.0V
2.4V
0.4V
2.0V
0.8V
AI00826
Figure 6. AC Testing Load Circuit
1.3V
1N914
DEVICE
UNDER
TEST
3.3kΩ
OUT
CL = 100pF
CL includes JIG capacitance
AI00828
Table 6. Capacitance(1)(2)
Symbol
Parameter
CIN Input Capacitance
COUT Output Capacitance
1. Sampled only, not 100% tested.
2. TA = 25 °C, f = 1 MHz.
Test Condition
VIN = 0V
VOUT = 0V
Min Max Unit
6
pF
12
pF