M27C801
DC and AC characteristics
Table 8. Programming mode DC characteristics(1) (2)
Symbol
Parameter
Test condition
Min.
Max.
ILI Input leakage current
VIL ≤VIN ≤VIH
±10
ICC Supply current
50
IPP Program current
E = VIL
50
VIL Input low voltage
–0.3
0.8
VIH Input high voltage
2
VCC + 0.5
VOL Output low voltage
IOL = 2.1mA
0.4
VOH Output high voltage TTL
IOH = –1mA
3.6
VID A9 voltage
11.5
12.5
1. TA = 25 °C; VCC = 6.25V ± 0.25V; VPP = 12.75V ± 0.25V
2. VCC must be applied simultaneously with or before VPP and removed simultaneously or after VPP.
Unit
µA
mA
mA
V
V
V
V
V
15/24