DC and AC parameters
Table 7.
AC Measurement Conditions
Parameter
Input Rise and Fall Times
Input Pulse Voltages
Input and Output Timing Ref. Voltages
M27W101
High Speed
≤ 10ns
0 to 3V
1.5V
Standard
≤ 20ns
0.4V to 2.4V
0.8V and 2V
TA = 25 °C, f = 1 MHz
Table 8. Capacitance (1)
Symbol
Parameter
Test Condition Min. Max. Unit
CIN
Input Capacitance
COUT
Output Capacitance
1. Sampled only, not 100% tested.
VIN = 0V
VOUT = 0V
Figure 6. AC Testing Input Output Waveform
High Speed
6
pF
12
pF
3V
1.5V
0V
Standard
2.4V
0.4V
Figure 7. AC Testing Load Circuit
1.3V
1N914
2.0V
0.8V
AI01822
DEVICE
UNDER
TEST
3.3kΩ
CL
OUT
14/23
CL = 30pF for High Speed
CL = 100pF for Standard
CL includes JIG capacitance
AI01823B