M27W401
4
DC and AC parameters
DC and AC parameters
TA = –40 to 85°C; VCC = 2.7V to 3.6V; VPP = VCC
Table 5. Read Mode DC Characteristics (1)
Symbol
Parameter
Test Condition
Min. Max. Unit
ILI Input Leakage Current
0V ≤ VIN ≤ VCC
ILO Output Leakage Current
0V ≤ VOUT ≤ VCC
ICC Supply Current
E = VIL, G = VIL, IOUT = 0mA,
f = 5MHz, VCC ≤ 3.6V
ICC1 Supply Current (Standby) TTL
E = VIH
ICC2
Supply Current (Standby)
CMOS
E > VCC – 0.2V, VCC ≤ 3.6V
±10
µA
±10
µA
15
mA
1
mA
15
µA
IPP Program Current
VPP = VCC
100
µA
VIL Input Low Voltage
VIH (2) Input High Voltage
–0.6 0.2VCC V
0.7VCC VCC + 0.5 V
VOL Output Low Voltage
IOL = 2.1mA
0.4
V
VOH Output High Voltage TTL
IOH = –400µA
2.4
V
1. VCC must be applied simultaneously with or before VPP and removed simultaneously or after VPP.
2. Maximum DC voltage on Output is VCC +0.5V.
TA = 25 °C; VCC = 6.25V ± 0.25V; VPP = 12.75V ± 0.25V
Table 6. Programming Mode DC Characteristics (1)
Symbol
Parameter
Test Condition
Min
Max
Unit
ILI Input Leakage Current
0 ≤ VIN ≤ VCC
±10
µA
ICC Supply Current
50
mA
IPP Program Current
E = VIL
50
mA
VIL Input Low Voltage
–0.3
0.8
V
VIH Input High Voltage
2.0
VCC + 0.5 V
VOL Output Low Voltage
IOL = 2.1 mA
0.4
V
VOH Output High Voltage TTL
IOH = –400 µA
2.4
V
VID A9 Voltage
11.5
12.5
V
1. VCC must be applied simultaneously with or before VPP and removed simultaneously or after VPP.
13/23