DC and AC parameters
8
DC and AC parameters
M29W128FH, M29W128FL
This section summarizes the operating measurement conditions, and the DC and AC
characteristics of the device. The parameters in the DC and AC characteristics Tables that
follow, are derived from tests performed under the Measurement Conditions summarized in
Table 18: Operating and AC measurement conditions. Designers should check that the
operating conditions in their circuit match the operating conditions when relying on the
quoted parameters.
Table 18. Operating and AC measurement conditions
M29W128FH, M29W128FL
Parameter
60
70
Unit
VCC supply voltage
Ambient Operating Temperature
Load capacitance (CL)
Input Rise and Fall Times
Input pulse voltages
Input and Output Timing Ref. voltages
Min
Max
Min
Max
2.7
3.6
2.7
3.6
V
−40
85
−40
85
°C
30
30
pF
10
10
ns
0 to VCC
VCC/2
0 to VCC
V
VCC/2
V
Figure 7. AC measurement load circuit
VPP
VCC
VCC
DEVICE
UNDER
TEST
0.1µF 0.1µF
25kΩ
25kΩ
CL
CL includes JIG capacitance
AI05558