DC and AC parameters
9
DC and AC parameters
M29W128GH, M29W128GL
This section summarizes the operating measurement conditions, and the DC and AC
characteristics of the device. The parameters in the DC and AC characteristics tables that
follow, are derived from tests performed under the measurement conditions summarized in
Table 22: Operating and AC measurement conditions. Designers should check that the
operating conditions in their circuit match the operating conditions when relying on the
quoted parameters.
Table 22. Operating and AC measurement conditions
M29W128GH, M29W128GL
Parameter
70 or 60(1) ns
80 ns
Unit
Min
Max
Min
Max
VCC supply voltage
VCCQ supply voltage (VCCQ ≤VCC)
Ambient operating temperature
Load capacitance (CL)
Input rise and fall times
Input pulse voltages
Input and output timing ref. voltages
1. Only available upon customer request.
2.7
3.6
2.7
3.6
V
2.7
3.6
1.65
3.6
V
−40
85
−40
85
°C
30
30
pF
10
10
ns
0 to VCCQ
VCCQ/2
0 to VCCQ
V
VCCQ/2
V
Figure 10. AC measurement load circuit
VPP
VCC
VCCQ
DEVICE
UNDER
TEST
0.1 µF 0.1 µF
25 kΩ
25 kΩ
CL
CL includes JIG capacitance
AI05558b