M40Z111, M40Z111W
DC and AC parameters
Table 6. DC characteristics
Sym
Parameter
Test condition(1)
M40Z111
M40Z111W
Unit
Min Typ Max Min
Typ
Max
ICC Supply current
ICCDR
Data retention mode
current
Outputs open
3
6
150
2
4
mA
150 nA
ILI Input leakage current
0 V ≤ VIN ≤ VCC
±1
ILO(2) Output leakage current 0 V ≤ VOUT ≤ VCC
±1
±1 µA
±1 µA
IOUT1 VOUT current (active)
VOUT > VCC –0.3
VOUT > VCC –0.2
160
100
100 mA
65 mA
) IOUT2
VOUT current (battery
backup)
VOUT > VBAT –0.3
100
t(s VBAT Battery voltage
2.0 3.0
3.5
2.0
c VIH Input high voltage
2.2
VCC + 0.3 2.0
rodu VIL
VOH
P VOHB
te VOL
le THS
Obso VPFD
t(s) - VSO
Input low voltage
Output high voltage
VOH battery backup
Output low voltage
Threshold select voltage
Power-fail deselect
voltage (THS = VSS)
Power-fail deselect
voltage (THS = VOUT)
Battery back-up
switchover voltage
–0.3
IOH = –2.0 mA 2.4
IOUT2 = –1.0 µA 2.0 2.9
IOL = 4.0 mA
VSS
4.50 4.60
4.20 4.35
3.0
0.8
3.6
0.4
VOUT
4.75
4.50
–0.3
2.4
2.0
VSS
2.80
2.50
100
3.0
2.9
2.90
2.60
VPFD –
100 mV
µA
3.5
V
VCC +
0.3
V
0.8
V
V
3.6 V
0.4 V
VOUT V
3.00 V
2.70 V
V
uc 1. Valid for ambient operating temperature: TA = –40 to 85 °C; VCC = 4.5 to 5.5 V or 2.7 to 3.6 V (except where noted).
Obsolete Prod 2. Outputs deselected.
Doc ID 5676 Rev 5
13/20