M41ST87Y, M41ST87W
Figure 28. Power Down/Up Mode AC Waveforms
VCC
VPFD (max)
VPFD (min)
VSO
tF
tFB
tPD
PFO
VALID
tR
tRB
trec
VALID
INPUTS
RECOGNIZED
DON'T CARE
RECOGNIZED
RST
OUTPUTS
ECON
VALID
(PER CONTROL INPUT)
HIGH-Z
VALID
(PER CONTROL INPUT)
AI07085
Table 18. Power Down/Up AC Characteristics
Symbol
Parameter(1)
Min
Typ
Max
tF(2)
VPFD(max) to VPFD(min) VCC Fall Time
300
tFB(3)
VPFD(min) to VSS VCC Fall Time
10
tPD
EX at VIH before Power Down
0
tPFD
PFI to PFO Propagation Delay
15
25
tR
VPFD(min) to VPFD(max) VCC Rise Time
10
tRB
VSS to VPFD(min) VCC Rise Time
1
trec
Power up Deselect Time
96
98(4)
Note: 1. Valid for Ambient Operating Temperature: TA = –40 to 85°C; VCC = 4.5 to 5.5V or 2.7 to 3.6V (except where noted).
2. VPFD(max) to VPFD(min) fall time of less than tF may result in deselection/write protection not occurring until
200µs after VCC passes VPFD(min).
3. VPFD(min) to VSS fall time of less than tFB may cause corruption of RAM data.
4. Programmable (see Table 12., page 33)
Unit
µs
µs
µs
µs
µs
µs
ms
38/42