M41T80
5
DC and AC parameters
DC and AC parameters
This section summarizes the operating and measurement conditions, as well as the DC and
AC characteristics of the device. The parameters in the following DC and AC Characteristic
tables are derived from tests performed under the measurement conditions listed in the
relevant tables. Designers should check that the operating conditions in their projects match
the measurement conditions when using the quoted parameters.
Table 8.
Operating and AC measurement conditions (1)
Parameter
M41T80
Supply voltage (VCC)
Ambient operating temperature (TA)
Load capacitance (CL)
Input rise and fall times
Input pulse voltages
Input and output timing ref. voltages
1. Output Hi-Z is defined as the point where data is no longer driven.
2.0 to 5.5 V
–40 to 85 °C
100 pF
≤ 50 ns
0.2VCC to 0.8VCC
0.3VCC to 0.7VCC
Figure 12. AC measurement I/O waveform
0.8VCC
0.2VCC
0.7VCC
0.3VCC
Table 9. Capacitance
Symbol
Parameter(1)(2)
Min
Max
CIN
Input capacitance
7
COUT(3)
Output capacitance
10
tLP
Low-pass filter input time constant (SDA and SCL)
50
1. Effective capacitance measured with power supply at 5 V; sampled only, not 100% tested.
2. At 25 °C, f = 1 MHz.
3. Outputs deselected.
AI02568
Unit
pF
pF
ns
Doc ID 9074 Rev 5
19/27