M95640, M95320
Table 24. AC Characteristics (M95320-W and M95640-W, Device Grade 6)
Test conditions specified in Table 14. and Table 11.
Symbol Alt.
Parameter
Previous
Product
Version 3
Current
Product
Version4
New
Product
Version5,6
Unit
Min. Max. Min. Max. Min. Max.
fC
fSCK Clock Frequency
D.C. 2 D.C. 5 D.C. 10 MHz
tSLCH tCSS1 S Active Setup Time
200
90
30
ns
tSHCH tCSS2 S Not Active Setup Time
200
90
30
ns
tSHSL tCS S Deselect Time
200
100
40
ns
tCHSH tCSH S Active Hold Time
200
90
30
ns
tCHSL
S Not Active Hold Time
200
90
30
ns
tCH 1 tCLH Clock High Time
200
90
40
ns
tCL 1 tCLL Clock Low Time
200
90
40
ns
tCLCH 2 tRC Clock Rise Time
1
1
2 µs
tCHCL 2 tFC Clock Fall Time
1
1
2 µs
tDVCH tDSU Data In Setup Time
40
20
10
ns
tCHDX tDH Data In Hold Time
50
30
10
ns
tHHCH
Clock Low Hold Time after HOLD not Active 140
70
30
ns
tHLCH
Clock Low Hold Time after HOLD Active
90
40
30
ns
tCLHL
Clock Low Set-up Time before HOLD Active
0
0
0
ns
tCLHH
Clock Low Set-up Time before HOLD not
Active
0
0
0
ns
tSHQZ 2 tDIS Output Disable Time
250
100
40 ns
tCLQV tV Clock Low to Output Valid
150
60
40 ns
tCLQX tHO Output Hold Time
0
0
0
ns
tQLQH 2 tRO Output Rise Time
100
50
40 ns
tQHQL 2 tFO Output Fall Time
100
50
40 ns
tHHQV tLZ HOLD High to Output Valid
100
50
40 ns
tHLQZ 2 tHZ HOLD Low to Output High-Z
250
100
40 ns
tW
tWC Write Time
10
5
5 ms
Note: 1. tCH + tCL must never be lower than the shortest possible clock period, 1/fC(max).
2. Value guaranteed by characterization, not 100% tested in production.
3. Previous product version is identified by Process Identification letter ‘S’.
4. Current product version is identified by Process Identification letter ‘V’’.
5. New product version is identified by Process Identification letter ‘P’.
6. Preliminary Data.
30/42