MASWSS0191
GaAs SP3T 2.6 V CDMA-GPS Switch
0.5 - 3.0 GHz
Rev. V1
Electrical Specifications: TA = 25°C, VC = 0 V / 2.6 V5, Z0 = 50
Parameter
Test Conditions
Units Min. Typ.
Max.
Insertion Loss 6 (CELL Path)
Insertion Loss 6 (GPS Path)
Insertion Loss 6 (PCS Path)
820 MHz
1.5 GHz
1.9 GHz
820 MHz
1.5 GHz
1.9 GHz
820 MHz
1.5 GHz
1.9 GHz
dB
—
0.65
0.80
dB
—
0.70
—
dB
—
0.70
—
dB
—
0.95
1.1
dB
—
0.95
—
dB
—
0.95
—
dB
—
0.65
0.8
dB
—
0.70
—
dB
—
0.65
—
Isolation (CELL Path)
820 MHz
1.5 GHz
1.9 GHz
dB
30.0
32.0
—
dB
—
27.0
—
dB
—
24.5
—
Isolation (GPS Path)
820 MHz
1.5 GHz
1.9 GHz
dB
29.0
31.0
—
dB
—
26.0
—
dB
—
23.5
—
Isolation (PCS Path)
820 MHz
1.5 GHz
1.9 GHz
dB
25.0
27.0
—
dB
—
23.5
—
dB
—
21.5
—
Return Loss
All RF ports, DC – 2.5 GHz
dB
—
20
—
IP3
CELL Path
Two Tones +22 dBm / tone, 1 MHz Spacing, 820 MHz
dBm
—
58
—
PCS Path
Two Tones +22 dBm / tone, 1 MHz Spacing, 1880 MHz
dBm
—
59
—
Cross Modulation
Cell Band: Two-tone signal input: Tx1 = +22 dBm @ 820 MHz,
CELL Path
Tx2 = +22 dBm @ 821 MHz,
dBm
—
-113
—
RX interfere = -30 dBm @ 869 MHz.
Cross Modulation
PCS Band: Two-tone signal input: Tx1 = +18 dBm @ 1880
PCS Path
MHz, Tx2 = +18 dBm @ 1881 MHz,
dBm
—
-115
—
RX interfere = -30 dBm @ 1960 MHz.
P0.1 dB
CELL Path
GPS Path
PCS Path
820 MHz
1.5 GHz
1.9 GHz
dBm
—
37
—
dBm
—
35
—
dBm
—
35
—
Trise, Tfall
10% to 90% RF, 90% to 10% RF
µS
—
0.05
—
Ton, Toff
50% control to 90% RF, and 50% control to 10% RF
µS
—
0.07
—
Transients
In Band
mV
—
50
—
Control Current
|VC| = 2.6 V
µA
—
2
20
5. For positive voltage control, external DC blocking capacitors are required on all RF ports.
6. Insertion loss can be optimized by varying the DC blocking capacitor value, e.g. 1000 pF for 100 MHz - 1 GHz, 39 pF for 0.5 GHz - 3 GHz.
2
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support