GaAs SPDT Switch
DC - 3.0 GHz
RoHS
Compliant
MASWSS0192
V1
Electrical Specifications: TA = 25°C, VC = 0 V / 2.5 V 4, PIN = +10 dBm, Z0 = 50 Ω 5
Parameter
Insertion Loss 6
Isolation
VSWR
IP2
IP3
P1dB
Trise, Tfall
Ton, Toff
Transients
Control Current
RON
Gate Lag
Test Conditions
DC - 1.0 GHz
DC - 3.0 GHz
DC - 1.0 GHz
DC - 3.0 GHz
DC - 1.0 GHz
DC - 3.0 GHz
1 GHz, Two Tone, +7 dBm / tone, 20 MHz Spacing, 3 V
1 GHz, Two Tone, +7 dBm / tone, 20 MHz Spacing, 3 V
VC = 0.2 V / 2.7 V
VC = 0.2 V / 3.0 V
10% to 90% RF and 90% to 10% RF
50% control to 90% RF, 50% control to 10% RF
In-band
—
t > 90 mS after OFF to ON Switching (settled)
|∆Ron| between 15 µS and 90 mS after OFF to ON Switching
Units
dB
dB
dB
dB
Ratio
Ratio
dBm
dBm
dBm
dBm
nS
nS
mV
µA
Ω
Ω
Min.
—
—
20.0
9.5
—
—
—
—
—
—
—
—
—
—
—
—
Typ.
0.18
0.35
24.0
13.5
1.1:1
1.2:1
93
53
27.5
28.5
22
5
36
0.20
2.50
0.15
Max.
0.40
0.60
—
—
—
—
—
—
—
—
—
—
—
5
4.7
0.7
4. Alternate voltage operation of VC = 0 V / 5 V or -5 V / 0 V will yield similar insertion loss, isolation, VSWR, switching, RON, and gate lag results.
5. For positive voltage control, external DC blocking capacitors are required on all RF ports.
6. Insertion loss can be optimized by varying the DC blocking capacitor value, e.g. 1000 pF for 100 MHz - 1 GHz, 39 pF for 0.5 - 3 GHz.
Truth Table 7,8
Control
V1
1
Control
V2
0
RFC-RF1
On
RFC-RF2
Off
0
1
Off
On
7. Differential voltage, V (state 1) - V (state 0), must be 2.5 V
minimum, but must not exceed 8.5 V.
8. 0 = 0 V to 0.5 V; 1 = 2.5 V to 5 V or
0 = -5 V to -2.5 V, 1 = -0.5 to 0 V.
Qualification
Qualified to M/A-COM specification REL-201,
Process Flow –2.
Handling Procedures
Please observe the following precautions to avoid
damage:
Static Sensitivity
Gallium Arsenide Integrated Circuits are sensitive
to electrostatic discharge (ESD) and can be
damaged by static electricity. Proper ESD control
techniques should be used when handling these
devices.
2
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.