Qdatasheet_Logo
Integrated circuits, Transistor, Semiconductors Search and Datasheet PDF Download Site

MCC200-16IO1 View Datasheet(PDF) - IXYS CORPORATION

Part Name
Description
MFG CO.
MCC200-16IO1
IXYS
IXYS CORPORATION IXYS
'MCC200-16IO1' PDF : 3 Pages View PDF
1 2 3
Thyristor Modules
MCC 200
MCD 200
ITRMS = 2x340 A
ITAVM = 2x196 A
VRRM = 1400-1800 V
VRSM
VDSM
V
VRRM
VDRM
V
Type
1500 1400 MCC 200-14io1 MCD 200-14io1
1700 1600 MCC 200-16io1 MCD 200-16io1
1900 1800 MCC 200-18io1 MCD 200-18io1
3 67 1 542
MCC
3
MCD
1 542
3
2
1
67
54
Symbol
Conditions
Maximum Ratings
ITRMS / IFRMS
ITAVM / IFAVM
ITSM / IFSM
i2dt
(di/dt)cr
(dv/dt)cr
PGM
PGAV
VRGM
TVJ
TVJM
Tstg
VISOL
Md
TVJ = TVJM
TC = 90°C; 180° sine
TC = 85°C; 180° sine
TVJ = 45°C;
VR = 0
t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
TVJ = TVJM
VR = 0
t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
TVJ = 45°C;
VR = 0
t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
TVJ = TVJM;
VR = 0
t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
TVJ = TVJM;
repetitive; IT = 500 A
f = 50Hz; tP = 200µs;
VD = 2/3 VDRM;
IG = 0.5 A;
diG/dt = 0.5 A/µs
non repetitive; IT = 500 A
TVJ = TVJM; VDR = 2/3 VDRM
RGK = ; method 1 (linear voltage rise)
TVJ = TVJM; tP = 30 µs
IT = ITAVM; tP = 500 µs
340
196
216
8000
8600
7000
7500
320 000
311 000
245 000
236 000
100
500
1000
120
60
20
A
A
A
A
A
A
A
A2s
A2s
A2s
A2s
A/µs
A/µs
V/µs
W
W
W
10
V
-40...+125
°C
125
°C
-40...+125
°C
50/60 Hz, RMS;
IISOL 1 mA;
t = 1 min
t=1s
Mounting torque (M6)
Terminal connection torque (M6)
3000
V~
3600
V~
2.25-2.75/20-25 Nm/lb.in.
4.5-5.5/40-48 Nm/lb.in.
Weight
Typical including screws
125
g
Data according to IEC 60747 and refer to a single thyristor/diode unless otherwise stated.
IXYS reserves the right to change limits, test conditions and dimensions
© 2004 IXYS All rights reserved
Features
International standard package
Direct copper bonded Al2O3 -ceramic
base plate
Planar passivated chips
Isolation voltage 3600 V~
UL registered, E 72873
Keyed gate/cathode twin pins
Applications
Motor control
Power converter
Heat and temperature control for
industrial furnaces and chemical
processes
Lighting control
Contactless switches
Advantages
Space and weight savings
Simple mounting
Improved temperature and power
cycling
Reduced protection circuits
1-3
Share Link: GO URL