Crane Aerospace & Electronics Power Solutions
MFL Single and Dual DC/DC Converters
28 Volt input – 65 Watt
Electrical Characteristics: –55°C to +125° C TC, 28 VDC VIN, 100% load, free run, unless otherwise specified.
single output models
PARAMETER
CONDITIONS
OUTPUT VOLTAGE
OUTPUT CURRENT
OUTPUT POWER
OUTPUT RIPPLE
10 kHz - 2 MHz
LINE REGULATION
LOAD REGULATION
VIN = 16 to 40 VDC
VIN= 16 to 40 VDC
TC = 25°C
TC = -55°C TO +125°C
VIN = 16 TO 40 VDC
NO LOAD TO FULL
INPUT VOLTAGE
NO LOAD TO FULL
CONTINUOUS
TRANSIENT 120 msec.1, 2
INPUT CURRENT
NO LOAD
INHIBITED–INH1
INHIBITED–INH2
INPUT RIPPLE
CURRENT
10 kHz - 10 MHz
EFFICIENCY
LOAD FAULT
TC = 25°C
TC = -55°C TO +125°C
POWER DISSIPATION
SHORT CIRCUIT
TC = 25°C
RECOVERY 1
STEP LOAD
RESPONSE
50% - 100% - 50%
TRANSIENT
RECOVERY 1, 3
STEP LINE
RESPONSE 1
START-UP 5
CAPACITIVE LOAD 1, 6
16 - 40 -16 VDC
TRANSIENT 4
RECOVERY 3
DELAY
OVERSHOOT 1
TC = 25°C
MFL2815S
MIN TYP MAX
14.55 15.00 15.45
0
—
4.33
0
—
65
—
30
85
—
45
110
—
0
20
—
0
20
16
28
40
—
—
50
—
50
100
—
9
14
—
35
70
—
15
50
84
87
—
82
—
—
—
10
16
—
1.5
4
—
500 600
—
1.5
3.0
—
250 500
—
200 300
—
3.5
6
—
0
50
—
— 1000
MFL2828S
MIN TYP MAX
27.16 28.00 28.84
0
—
2.32
0
—
65
—
100 200
—
—
275
—
20
60
—
20
75
16
28
40
—
—
50
—
60
100
—
9
14
—
35
70
—
20
50
83
86
—
81
—
—
—
7
14
—
1.0
4
—
800 1400
—
1.5
3.0
—
250 800
—
200 400
—
3.5
6
—
0
100
—
— 1000
UNITS
VDC
A
W
mV p-p
mV
mV
VDC
V
mA
mA p-p
%
W
ms
mV pk
ms
mV pk
µs
ms
mV pk
µF
Notes
1. Guaranteed by design, not tested.
2. Unit will shut down above approximately 45V but will be undam-
aged and will restart when voltage drops into normal range.
3. Recovery time is measured from application of the transient to the
point at which Vout is within 1% of final value.
4. Transition time 100 µs ±20%.
5. Tested on release from inhibit.
6. Shall not compromise DC performance.
www.craneae.com/interpoint
Page 7 of 13
MFL Rev E - 20101026