DC/DC CONVERTERS MHF+ SERIES TRIPLE
15 WATT
Electrical Characteristics: 25°C Tc, 28 VDC Vin, 100% load, free run, unless otherwise specified.
PARAMETER
OUTPUT VOLTAGE
OUTPUT CURRENT1
OUTPUT POWER2
OUTPUT RIPPLE
VOLTAGE
LINE REGULATION3
VIN = MIN. TO MAX.
LOAD REGULATION3, 4
CROSS REGULATION5
INPUT VOLTAGE
INPUT CURRENT
INPUT RIPPLE CURRENT
EFFICIENCY
LOAD FAULT6
STEP LOAD
RESPONSE3, 7, 8
START-UP3,
CONDITION
MAIN
+ AUXILIARY
AUXILIARY
MAIN
+ AUXILIARY
AUXILIARY
TOTAL
MAIN
+ AUXILIARY
AUXILIARY
TOTAL
10 kHz to 2 MHz
MAIN
10 kHz to 2 MHz ± AUXILIARY
MAIN
±AUXILIARY
MAIN
± AUXILIARY
AUXILIARY
CONTINUOUS
TRANSIENT 120 ms
NO LOAD3
FULL LOAD
INHIBITED3
10 kHz to 10 MHz
POWER DISSIPATION
MAIN3
±AUXILIARY
TRANSIENT
MAIN
± AUXILIARY
RECOVERY MAIN
RECOVERY ±AUX.
DELAY EACH OUTPUT
MHF+28512T
MIN
TYP MAX
4.95
5.0
5.05
11.64 12.0 12.36
11.64 12.0 12.36
0
1.5
0.416
0.416
2.125
7.5
5
5
15
20
75
30
90
25
75
120
240
25
60
120
240
1200
16
28
48
80
20
35
705
724
3
5
20
50
74
76
12
12
850
750
5
8
2
3
10
25
MHF+28515T
MIN TYP MAX
4.925
5.0
5.05
14.55 15.0 15.45
14.55 15.0 15.45
0
1.5
0.333
0.333
2.0
7.5
5
5
15
20
75
30
112
25
75
150
300
25
60
150
300
1500
16
28
48
80
20
35
705
724
3
5
20
50
74
76
12
12
850
750
5
8
2
3
10
25
UNITS
VDC
A
W
mV p-p
mV
mV
mV
VDC
V
mA
mA p-p
%
W
mV pk
ms
ms
Notes
1. The sum of the 12 volt auxiliary output currents may not exceed 625 mA.
The sum of the 15 volt auxiliary output currents may not exceed 500 mA.
2. The sum of the auxiliary output power may not exceed 7.5 watts.
3. Case temperature 55°C to +125°C.
4. Load regulation for the +5 is specified at 0.0 to 1.5 A with the aux. both held
at 3.76 W (313 mA for the ±12, 250 mA for the ±15). Load regulation for the
aux. is specified as both aux. from 0.0 to 3.76 W (313 mA for ±12, 250 mA
for ±15) at the same time with the +5 held at 1.5 A.
5. Cross regulation only occurs between the two auxiliaries and is measured on
aux. +5 is held constant at 1.0 A. Cross regulation is specified for two
conditions:
Negative aux.= 3.76 W; positive aux.= 0.37 W to 3.76 W.
Negative aux. = 0.37 W to 3.76 W; positive aux. = 3.76 W.
6. Load fault = <0.05 .
7. Transition time is 2 10 µs.
8. Time to settle to within 1% of Vout final value.
3