NXP Semiconductors
PCF2127
Accurate RTC with integrated quartz crystal for industrial applications
8.6.1.1 Standard mode
If VDD > VBAT OR VDD > Vth(sw)bat: Voper(int) is at VDD potential.
If VDD < VBAT AND VDD < Vth(sw)bat: Voper(int) is at VBAT potential.
EDFNXSEDWWHU\RSHUDWLRQ
9''
9RSHULQW
9%$7
LQWHUQDORSHUDWLQJYROWDJH9RSHULQW
9RSHULQW
9WKVZEDW
9
9'' 9
%)
,17
FOHDUHGYLDLQWHUIDFH
DDM
Fig 6.
Vth(sw)bat is the battery switch threshold voltage. Typical value is 2.5 V. In standard mode, the
battery switch-over works only for VDD > 2.5 V.
VDD may be lower than VBAT (for example VDD = 3 V, VBAT = 4.1 V).
Battery switch-over behavior in standard mode with bit BIE set logic 1 (enabled)
PCF2127
Product data sheet
All information provided in this document is subject to legal disclaimers.
Rev. 8 — 19 December 2014
© NXP Semiconductors N.V. 2014. All rights reserved.