PI6C185-01B
112233445566778899001122334455667788990011223344556677889900112211223344556677889900112233445566778899001122334455667788990011221122334455667788990011223344556677889900112233445566778899001122112233445566778899P0011r22e33c4455i66s77i88o99n001122133-445556677C8899l00o11c2211k2233B4455u6677f88f99e00r1122
2-Wire I2C Control
The I2C interface permits individual enable/disable of each clock
output and test mode enable.
The PI6C185-01B, a slave receiver device, cannot be read back.
Sub addressing is not supported. To change one of the control
bytes, all preceding bytes must be sent
Every byte put on the SDATA line must be 8-bits long (MSB first),
followed by an acknowledge bit generated by the receiving
device.
During normal data transfers SDATA changes only when SCLK is
LOW. Exceptions: A HIGH to LOW transition on SDATA while
SCLK is HIGH indicates a “start” condition. A LOW to HIGH
transition on SDATA while SCLK is HIGH is a “stop” condition
and indicates the end of a data transfer cycle.
1
Each data transfer is initiated with a start condition and ended with
2 a stop condition. The first byte after a start condition is always a
7-bit address byte followed by a read/write bit. (HIGH = read from
addressed device, LOW = write to addressed device). If the device’s
own address is detected, PI6C185-01B generates an acknowledge
by pulling SDATA line LOW during ninth clock pulse, then
3 accepts the following data bytes until another start or stop condition
is detected.
Following acknowledgement of the address byte (0D2H), two
more bytes must be sent:
1. “Command Code” byte & 2. “Byte Count” byte.
4
Although the data bits on these two bytes are “don’t care,” they
must be sent and acknowledged.
5
Maximum Ratings
(Above which the useful life may be impaired.
For user guidelines, not tested.)
StorageTemperature ...................................... 65°Cto+150°C
Ambient Temperature with Power Applied ........ 0°Cto+70°C
3.3V Supply Voltage to Ground Potential ........... 0.5Vto+4.6V
DC Input Voltage .............................................. 0.5Vto+4.6V
6
Note:
Stresses greater than those listed under MAXIMUM RATINGS
may cause permanent damage to the device. This is a stress rating
7 only and functional operation of the device at these or any other
conditions above those indicated in the operational sections of
this specification is not implied. Exposure to absolute maximum
rating conditions for extended periods may affect reliability.
8
Supply Current (VDD = +3.465V, CLOAD = Max.)
Symbol Parameter
Test Condition
Min. Typ. Max. Units
9
IDD Supply Current BUF_IN = 0 MHz
IDD Supply Current BUF_IN = 66.66 MHz
IDD Supply Current BUF_IN = 100.0 MHz
IDD Supply Current BUF_IN = 133.3 MHz
3
70
mA
120
200
10
11
12
13
14
15
3
PS8466 05/03/00