SC5010H
Pin Descriptions
Pin #
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
Pin Name Pin Function
VCC
EN
UVLO
SCP
BG
Input bias voltage supply for the IC — accepts 4.5-5.5V inputs. Add a 1µF or larger ceramic bypass capacitor from
this pin to ground.
Logic high enable pin — pull logic high to enable the device or pull low to disable and maintain low shutdown
current.
Input under-voltage lockout pin — Device is disabled when this pin is less than 1.23V (nominal). Add a resistor
divider from this pin to the input voltage and AGND, respectively.
Short circuit LED protection programming pin. Shorted LED protection disables the individual channel when the
current sink voltage exceeds the programmed voltage threshold. Adding resistor divider from this pin to BG and
AGND programs the shorted-LED protection up to 20 X the VSCP voltage. Pulling the pin high to VCC disables the
SCP feature on all channels.
1.23V bandgap output pin — Connect a 1µF ceramic bypass capacitor from this pin to ground.
FSET
AGND
CPLL
SYNC
Step-up (boost) frequency set pin — Connect a resistor from this pin to ground to set the frequency from 200kHz
to 2.2MHz.
Analog ground pin — tie this pin to analog (quiet) ground isolated from the step-up (boost) converter switching
current path.
Compensation for the internal PLL — connect a compensation resistor and capacitor from this pin to ground. This
pin can be left floating if not used.
SYNC input pin — feeding the SYNC signal (30Hz - 100kHz) to this input results in internal PLL being synchronized
to the SYNC signal. This pin can be left floating if not used.
SCL
I2C serial clock input — this pin must be connected to ground if not used.
SDA
I2C serial data input — this pin must be connected to ground if not used.
ISET
LED current programming pin — connect an external resistor to ground to program the current in the LED strings.
For more details please refer to LED String Peak Current Programming on page 16.
Logic low fault status pin — open-drain output is latched low when fault condition is detected: Open/Short LED,
FLT
Shorted String, OVP or OTP. Fault status can be reset by removing fault condition(s) and toggling the EN, VCC or
UVLO pins. This pin can be left floating if not used.
PWMI
PWM dimming control input
Regulated current sink LED channel 8 — connect this pin to the cathode of the bottom LED in string 8.
IO8
Connect pin to ground to disable this LED string.
Regulated current sink LED channel 7 — connect this pin to the cathode of the bottom LED in string 7.
IO7
Connect pin to ground to disable this LED string.
IO6
Regulated current sink LED channel 6 — connect this pin to the cathode of the bottom LED in string 6.
Connect pin to ground to disable this LED string.
IO5
Regulated current sink LED channel 5 — connect this pin to the cathode of the bottom LED in string 5.
Connect pin to ground to disable this LED string.
IO4
Regulated current sink LED channel 4 — connect this pin to the cathode of the bottom LED in string 4.
Connect pin to ground to disable this LED string.
12