SC900
POWER MANAGEMENT
Electrical Characteristics (Cont.)
Unless otherwise noted: VIN = 3.7V, EN = VIN, TA = -40 to 85°C. Typical values are at TA = +25°C.
Parameter
Symbol
Condition
Min Typ Max Units
LDO Regulator E
Output Voltage Accuracy
VOAE
1.45V < VOUT < 3.00V
VOUT +0.15V < VIN < 5.5V
-3
IOUT = 1mA, TA = 25OC
+3 %
Output Voltage Accuracy at 2.80V
(DAC=11011)
VOASE
IOUT = 1mA
-2
IOUT = 150mA, VOUT + 0.5V < VIN < 5.5V -3.5
+2 %
+3.5 %
Maximum Output Current
IOMAXE
150
mA
Default Setting: OFF
VOE
2.80
V
Line Regulation at 2.80V
LINEREGE IOUT = 1mA, VOUT +0.15V < VIN < 5.5V
2.5 12 mV
Load Regulation at 2.80V
LOADREGE
1mA < IOUT < 150mA
-3 -20 mV
I2C Interface
Interface complies with slave mode I2C interface as described by Philips I2C specification version 2.1 dated January
2000.
Digital Input Voltage
SDA Output Low Level
Digital Input Current
I/O Pin Capacitance
I2C Timing
VIL
0.4 V
VIH
1.6
V
IDIN(SDA) = 3mA
0.4 V
IDIN(SDA) = 6mA
0.6 V
IDG
-0.2
0.2 µA
CIN
10
pF
Clock Frequency
SCL
400 kHz
SCL Low Period
SCL High Period
Data Hold Time
Data Setup Time
Setup Time for Repeated
Start Condition
tLOW
tHIGH
tHD_DAT
tSU_DAT
tSU_STA
1.3
µs
0.6
µs
0
µs
100
ns
0.6
µs
Hold Time for Repeated
Start Condition
tHD_STA
0.6
µs
SetupTime for Stop Condition
Bus-Free Time Between
STOP and START
tSU_STO
tBUF
0.6
µs
1.3
µs
2005 Semtech Corp.
5
www.semtech.com