Si7005
4.3. Linearization
Capacitive relative humidity sensors require linearization. The Si7005 accuracy specification (Table 4) applies after
correction of non-linearity errors. The recommended linearization technique is to correct the measured relative
humidity value with a 2nd order polynomial; the linear relative humidity (RH) value is calculated as follows:
RHLinear = RHValue RHValue2 A2 + RHValue A1 + A0
Where:
RHLinear is the corrected relative humidity value in %RH
RHValue is the uncorrected (measured) relative humidity value in %RH
A2, A1, and A0 are unit-less correction coefficients derived through characterization of Si7005s by Silicon
Laboratories; their values depend on whether compensation for a typical solder reflow is required
The values for the correction coefficients are shown in Table 10.
Table 10. Linearization Coefficients
Coefficient
A0
A1
A2
Value
–4.7844
0.4008
–0.00393
Rev. 1.3