NEW Product
OUTPUT
POWER
(MAX.)
99 W
INPUT
VOLTAGE
8-14 Vdc
OUTPUT
VOLTAGE
OUTPUT
CURRENT
(MIN.)
0.8-3.63 Vdc
0A
OUTPUT
CURRENT
(MAX.)
30 A
EFFICIENCY
(TYP.)
93%
REGULATION
LINE
LOAD
MODEL
NUMBER (2,3)
±0.2%
±1.5% SIL30E-12W3V3-VJ
Part Number System with Options
SIL30E-12W3V3-VJ
Product Family
SIL = Single In Line
Rated Output Current
30 = 30 Amps
Performance
E = Enhanced Performance
Packaging Options
J = Pb-free (RoHS 6/6 compliant) (2)
Mounting Option
V = Vertical
Output Voltage
0.8 Vdc to 3.63 Vdc
Type of Output
W = Wide
Input Voltage
12 = 8 Vdc to 14 Vdc
Output Voltage Adjustment of the SIL30E-12W3V3 Series
The ultra-wide output voltage trim range offers major advantages to users who
select the SIL30E-12W3V3. It is no longer necessary to purchase a variety of
modules in order to cover different output voltages. The output voltage can be
trimmed in a range of 0.8 Vdc to 3.63 Vdc. When the SIL30E-12W3V3
converter leaves the factory the output has been adjusted to the default
voltage of 0.8 V.
Notes
1 The SIL30E features a ‘Positive Logic’ Remote ON/OFF operation. If not
using the Remote ON/OFF pin, leave the pin open (the converter will be
on). The Remote ON/OFF pin is referenced to ground.
The following conditions apply for the SIL30E:
Configuration
Remote pin open circuit
Remote pin pulled low [Von/off < 0.8 V]
Remote pin pulled high [Von/off >2.8 V]
Converter Operation
Unit is ON
Unit is OFF
Unit is ON
A ‘Negative Logic’ Remote ON/OFF version is also possible with this
converter. Please consult the factory for details.
2 TSE RoHS 5/6 (non Pb-free) compliant versions may be available on
special request, please contact your local sales representative for details.
3 NOTICE: Some models do not support all options. Please contact your
local Artesyn representative or use the on-line model number search tool
at http://www.artesyn.com/powergroup/products.htm to find a suitable
alternative.
Notes
A The derating curve represents the condition at which internal components
are within the Artesyn derating guidelines.
B Characteristic data has been developed from actual products tested at
25 °C. This data is considered typical data for the converter.
File Name: sil30e_12.pdf Rev (02): 16 Dec 2005