Qdatasheet_Logo
Integrated circuits, Transistor, Semiconductors Search and Datasheet PDF Download Site

SN260 View Datasheet(PDF) - STMicroelectronics

Part Name
Description
MFG CO.
SN260
ST-Microelectronics
STMicroelectronics ST-Microelectronics
'SN260' PDF : 88 Pages View PDF
SN260
EmberZNet serial protocol
Table 30. EmberStatus (continued)
Structure
EMBER_ERR_BOOTLOADER_TRAP_UNKNOWN
EMBER_ERR_BOOTLOADER_NO_IMAGE
EMBER_TOO_MANY_CONNECTIONS
EMBER_CONNECTION_OPEN
EMBER_CONNECTION_FAILED
EMBER_CONNECTION_CLOSED
EMBER_CONNECTION_CLOSING
EMBER_DELIVERY_FAILED
EMBER_BINDING_INDEX_OUT_OF_RANGE
EMBER_INVALID_BINDING_TERMINAL
EMBER_INVALID_BINDING_INDEX
EMBER_TERMINAL_HAS_MULTIPLE_
BINDINGS
EMBER_INVALID_CALL
EMBER_COST_NOT_KNOWN
EMBER_MAX_MESSAGE_LIMIT_REACHED
EMBER_CONNECTION_NOT_YET_OPEN
EMBER_MESSAGE_TOO_LONG
EMBER_BINDING_IS_ACTIVE
EMBER_EUI64_NOT_AVAILABLE
EMBER_INCOMING_SEQUENCED_MESSAGES
LOST
EMBER_ADC_CONVERSION_DONE
EMBER_ADC_CONVERSION_BUSY
EMBER_ADC_CONVERSION_DEFERRED
EMBER_ADC_NO_CONVERSION_PENDING
Field
0x59
0x5A
0x60
0x61
0x63
0x64
0x65
0x66
0x69
0x6B
0x6C
0x6F
0x70
0x71
0x72
0x73
0x74
0x75
0x76
Description
Bootloader received an invalid message (failed attempt
to go into bootloader).
Bootloader cannot complete the bootload operation
because either an image was not found or the image
exceeded memory bounds.
EMBER_TRANSPORT_CONNECTION_COUNT limit has
been reached.
A connection has either been opened or is already open.
A connection experienced a catastrophic error. The
connection is now closed and messages may have been
lost.
Transport layer successfully closed a connection.
Transport layer is in process of closing a connection
(waiting for a response from the remote device).
Transport layer attempted to send or deliver a message,
but it failed.
This binding index is out of range of the current binding
table.
Could not set or find a binding index given the specified
terminal.
An invalid binding table index was given to a function.
Multiple binding table entries were found for the specified
terminal.
API call is not allowed given the current state of the stack
(for example, opening a connection from a sleepy node.).
Link cost to a node is not known.
Maximum number of in-flight messages (such as
EMBER_TRANSPORT_PACKET_COUNT) has been
reached.
A connection is not open yet.
Message to be transmitted is too big to fit into a single
over-the-air packet.
Application is trying to delete or overwrite a binding that
is in use.
EUI64 is not available in the current packet.
0x77 One or more sequenced messages failed to be received.
0x80
0x81
0x82
0x84
Conversion is complete.
Conversion cannot be done because a request is being
processed.
Conversion is deferred until the current request has been
processed.
No results are pending.
47/88
Share Link: GO URL