ST5088
Table 10: Control Register CR8 Functions
7 65 43 21 0
f17 f16 f15 f14 f13 f12 f11 f10
Function
msb
lsb Binary equivalent of the decimal number used to calculate f1
Table 11: Control Register CR9 Functions
7 65 43 21 0
f27 f26 f25 f24 f23 f22 f21 f20
Function
msb
lsb Binary equivalent of the decimal number used to calculate f2
Table 12: Control Register CR10 Functions
7 65 43 21 0
GLS ACE VT1 VT0 FD1 FD0 DFT HFT
Function
1
+27 dB into LH Path
0
(*) +9dB into LH Path
1
Anticlipping ON
0
(*) Anticlipping OFF
00
01
10
11
(*) -15dm0 Anticlipping Threshold
-13dm0 Anticlipping Threshold
-9dm0 Anticlipping Threshold
-7dm0 Anticlipping Threshold
00
01
10
11
(*) 256ms Gain Recovery Time Constant / (4Hz)
128ms Gain recovery Time Constant / (8Hz)
32ms Gain Recovery Time Constant / (31Hz)
16ms Gain Recovery Time Constant / (62Hz)
0 0 (*) Standard Frequency Tone Range
0 1 Halved Frequency Tone Range
1 0 Doubled Frequency Tone Range
1 1 Forbidden
(*) Default values inserted into the Register at Power On.
17/33