ST5088
DISTORTION
Symbol
STDx
STDr
Parameter
Signal to Total Distortion
SDFx
SDFr
IMD
Single Frequency Distortion
transmit
Single Frequency Distortion
receive
Intermodulation
Test Condition
Sinusoidal Test Methode
(measured using C message
weighting Filter)
Level = 0 dBm0 to - 30 dBm0
Level = - 40 dBm0
Level = - 45 dBm0
0 dBm0 input signal
Min. Typ. Max. Unit
36
dBC
29
dBC
24
dBC
-46
dB
0 dBm0 input signal
-46
dB
Loop-around measurament
Voltage at VMIC = -4 dBm0
to -21 dBm0, 2 Frequencies in
the range 300 - 3400 Hz
-41
dB
CROSSTALK
Symbol
CTx-r
Parameter
Transmit to Receive
CTr-x
Receive to Transmit
TAPE RECORDER
Symbol
GTRO RX
GTRO TX
Parameter
Receive TRO Output
Transmit TRO Output
Test Condition
Min. Typ. Max. Unit
Transmit Level = 0 dBm0,
f = 300 - 3400 Hz
DR = QuietPCM Code
-65
dB
Receive Level = 0 dBm0,
f = 300 - 3400 Hz; VMIC = 0V
-65
dB
Test Condition
DR = 0dBm0
DX = 0dBm0
Min.
200
200
Typ.
245
246
Max.
275
275
Unit
mVRMS
mVRMS
APPLICATION NOTE FOR MICROPHONE CONNECTIONS
The 4 connection modes (since the MIXED MODE is symmetrical with respect to MIC1 and MIC2) allow
one microphone at a time to be selected via the VS bit (bit 7 of Control Register CR4).
30/33