3.2
3.3
STG3157
AC Electrical characteristics
AC Electrical characteristics
CL = 50 pF, RL = 500 Ω
Table 6. AC specification
Symbol
Parameter
Test conditions
VCC(V)
tLH, tHL
tPZH,
tPZL
tPLZ,
tPHZ
tD
Q
Propagation delay
Output enable
time (D to Sn)
Output disable
time (D to Sn)
Break-before-
make time delay
Charge injection
1.65-1.95
2.3-2.7
3.0-3.3
4.5-5.5
1.65-1.95
2.3-2.7
3.0-3.3
4.5-5.5
1.65-1.95
2.3-2.7
3.0-3.3
4.5-5.5
1.65-5.5
5
3.3
VI = Open
TA = 25 °C
Min. Typ. Max.
1.2
0.8
0.3
7
15
3.5
11
2.5
7
1.7
5.2
3
10
2
7
1.5
5
1.7
3.5
0.5
23
19
Value
-40 to 85 °C
Min. Max.
1.2
0.8
0.3
7
20
3.5
14
2.5
7.6
1.7
5.7
3
13
2
7.5
1.5
5.3
1.7
3.8
0.5
Analog switch characteristics
CL = 5 pF, RL = 50 Ω, TA = 25 °C
-55 to 125 °C Unit
Min. Max.
1.8
ns
1.2
0.5
7
27
3.5
17
ns
2.5
9
1.7
7
3
16
2
9
ns
1.5
6.5
1.7
5
0.5
ns
pC
Symbol
Parameter
OIRR Off isolation
Xtalk Crosstalk
BW - 3 dB bandwidth
CIN
Control pin input
capacitance
CSn Sn port capacitance
CD
D port capacitance
when switch is enabled
Table 7. Analog switch characteristics
Test conditions
VCC (V)
1.65-5.5
1.65-5.5
1.65-5.5
RL = 50 Ω f
= 10 MHz
RL = 50 Ω f
= 10 MHz
RL = 50 Ω
Value
TA = 25 °C
-40 to 85 °C
Min. Typ. Max. Min. Max.
-57
-54
250
-55 to 125 °C
Min. Max.
Unit
dB
dB
MHz
5
5.0
f = 1 MHz
13
pF
5.0
f = 1 MHz
21
DS2882 - Rev 3