STV6886
VERTICAL SECTION
Operating Conditions
Symbol
Parameter
Test Conditions
Min. Typ. Max. Units
RLOAD
Minimum Load for less than 1% Vertical
Amplitude Drift
Pin 20
65
MΩ
Electrical Characteristics (VCC = 12V, Tamb = 25°C)
Symbol
Parameter
Test Conditions
Min. Typ. Max. Units
VRB
Voltage at Ramp Bottom Point
Pin 22
2.1
V
VRT
Voltage at Ramp Top Point (with Sync) Pin 22
5.1
V
VRTF
Voltage at Ramp Top Point (without
Sync)
Pin 22
VRT-
0.1
V
VSTD
VFRF
ASFR
RAFD
Rlin
VPOS
Vertical Sawtooth Discharge Time
Vertical Free Running Frequency (12)
AUTO-SYNC Frequency (13)
Pin 22, C22 = 150nF
Pin 22, C22 = 150nF
C22 = 150nF ±5%
Ramp Amplitude Drift Versus Frequency C22 = 150nF
at Maximum Vertical Amplitude (11)
50Hz< f < 120Hz
Ramp Linearity on Pin 22 (12)
2.5V < V27 < 4.5V
Sub Address 06
Vertical Position Adjustment Voltage (Pin Byte 00000000
23 - VOUT mean value)
Byte 01000000
Byte 01111111
70
µs
100
Hz
50
120 Hz
200
ppm/
Hz
0.5
%
3.2 Tbd V
3.6
V
Tbd 4.0
V
VOR
Vertical Output Voltage
(peak-to-peak on Pin 23)
Sub Address 05
Byte 10000000
Byte 11000000
Byte 11111111
2.15 Tbd V
3.0
V
Tbd 3.9
V
VOI
Vertical Output Maximum Current
(Pin 23)
±5
mA
Max Vertical S-Correction Amplitude (TV Sub Address 07
dVS
is the vertical period)
(0xxxxxxx inhibits S-CORR
11111111 gives max S-CORR)
Byte 11111111
∆V/VPP at TV/4
∆V/VPP at 3TV/4
-3.5
%
+3.5
%
Sub Address 08
Ccorr
Vertical C-Corr Amplitude
(0xxxxxxx inhibits C-CORR)
∆V/VPP at TV/2
Byte 10000000
Byte 11000000
-3
%
0
%
Byte 11111111
+3
%
BRRANG DC Breathing Control Range (14)
V18
1
12
V
BRADj
Vertical Output Variation versus DC
Breathing Control (Pin 23)
V18 > VREF-V
1V<V18< VREF-V
0
%/V
-2.5
%/V
Note: 11 These parameters are not tested on each unit. They are measured during our internal qualification procedure.
Note:
Note:
12 Set Register 07 at Byte 0xxxxxxx (S correction inhibited) and Register 08 at Byte 0xxxxxxx (C correction
inhibited), to obtain a vertical sawtooth with linear shape.
13 This is the frequency range for which the vertical oscillator will automatically synchronize, using a single
capacitor value on Pin22 and Pin 20, and with a constant ramp amplitude.
Note: 14 When not used, the DC breathing control pin must be connected to 12V.