10. Reliability Test
No
Test Item
Test Condition
1 High Temperature Storage Test
Ta = +70 C, 240 hrs
2 Low Temperature Storage Test
Ta = -20 C, 240 hrs
High Temperature Operation
3
Test
Ta = +60 C, 240 hrs
Low Temperature Operation
4
Test
Ta = 0 C, 240 hrs
High Temperature & High
5
Humidity Operation Test
Ta = +40 C, 95%RH, 240 hrs
Thermal Cycling Test
6
(non-operating))
-25C →+25C →+70C,200 Cycles
30 min 5min 30min
Frequency:10 ~ 57 HZ /Vibration Width :0.075mm
Vibration Test
7
(non-operating)
58-500 HZ/ Gravity :9.8m/s²
Sweep time: 11 minutes
Test period: 3 hrs for each direction of X, Y, Z
Shock Test
8
(non-operating)
Electrostatic Discharge Test
9
(non-operating)
Gravity :490m/s²
Direction: ±X, ±Y, ±Z
Pulse Width :11ms,half sine wave
150pF,330Ω
Air : ±15KV;Contact : ±8KV
10 times/point,9 point/panel face
Ta: ambient temperature
[Judgement Criteria]
Under the display quality test conditions with normal operation state , there should be no
change which may affect practical display function.
T-51382D064-FW-P-AB
OPTREX CORPORATION
Page 16/17