Figure 11. EQ band1, normal- and DC-mode @ boost = 15 dB, fCenter = 62 Hz
16
dB
14
12
10
8
6
4
2
0
-1
1
10
100
1K
Note: The center frequency, Q, DC-mode and boost/cut can be set fully independently for each filter.
Hz 10K
2.7 Subwoofer Application
There is one separate subwoofer output. A low-pass filter stage at this output allows the selection of three dif-
ferent frequencies: 80/120/160Hz. A high Pass Filter stage is present in the main path with selectable 90/135/
180/215Hz frequencies. Both filters, the low-pass as well as the high-pass filter can be disabled and have but-
terworth characteristics so that their cutoff frequencies are not equal but shifted by the factor 1.125 to get a flat
frequency response (see Figure 12).
Figure 12. Subwoofer Application with Lowpass @ 80/120/160Hz and HighPass @ 90/135/180Hz
0.0
-10.0
-20.0
dB
-30.0
-40.0
-50.0
10.0
16/49
100.0
1.0K
Hz
10.0K