Diagnostics functional description
3
Diagnostics functional description
TDA7567PD
3.1
Turn-on diagnostic
It is activated at the turn-on (standby out) under I2C bus request. Detectable output faults
are:
Short to GND
Short to Vs
Short across the speaker
Open speaker
To verify if any of the above misconnections are in place, a subsonic (inaudible) current
pulse (Figure 5) is internally generated, sent through the speaker(s) and sunk back. The
turn-on diagnostic status is internally stored until a successive diagnostic pulse is requested
(after a I2C reading).
If the "standby out" and "diagnostic enable" commands are both given through a single
programming step, the pulse takes place first (power stage still in standby mode, low,
outputs= high impedance).
Afterwards, when the amplifier is biased, the PERMANENT diagnostic takes place. The
previous turn-on state is kept until a short appears at the outputs.
Figure 5.
Turn-on diagnostic: working principle
Vs~5V
I (mA)
Isource
Isource
CH+
CH-
Isink
Isink
~100mS
Measure time
t (ms)
Figure 6 and 7 show SVR and output waveforms at the turn-on (standby out) with and
without turn-on diagnostic.
Figure 6. SVR and output behavior (case 1: without turn-on diagnostic)
Vsvr
Out
Permanent diagnostic
acquisition time (100mS Typ)
12/30
Bias (power amp turn-on)
Diagnostic Enable
(Permanent)
FAULT
event
t
Read Data
I2CB DATA
Permanent Diagnostics data (output)
permitted time
Doc ID 16903 Rev 1