TDA9115
6.9 MISCELLANEOUS
VCC = 12V, Tamb = 25°C
Symbol
Parameter
Test Condit ions
Vertical blanking and horizon tal lock indication composite outpu t HLckVBk
ISinkLckBk
Sink current to HLckVBk pin
(35)
V.blank
H.lock
No
Yes
VOLckBk
Output voltage on HLckVBk output
Yes
Yes
No
No
Yes
No
Min.
Value
Typ.
100
0.1
1.1
5
6
Max.
Units
µA
V
V
V
V
Horizontal moiré canceller
VAC-HMoiré
Rext=10kΩ
H-moiré pulse amplitude on HMoiré pin
HMOIRE (Sad02):
x0000000b
x1111111b
0.1
V
2.1
V
VDC-HMoiré DC level on HMoiré pin
Vertical moiré canceller
Rext=10kΩ
0.1
V
VV-moiré
Amplitude of modulation of V-drive sig-
nal on VOut pin by vertical moiré.
VMOIRE (Sad0Bh):
x0000000b
x1111111b
0
mV
3
mV
Protection function s
VThrXRay
Input threshold on XRay input(36)
tXRayDelay
Delay time between XRay detection
event and protection action
7.65 7.9 8.2
V
2TH
VCCEn
VraCmCpv-uaplu(e37f)or start of operation at VCC
8.5
V
VCCDis
VraCmCpv-daoluwenf(o3r7)stop of operation at VCC
Control voltages on HPosF pin for Soft start/stop operation(18)
6.5
V
VHOn
Threshold for start/stop of H-drive sig-
nal
1
V
VBOn
Threshold for start/stop of B-drive sig-
nal
1.7
V
VHBNorm f
Threshold for full operational duty cycle
of H-drive and B-drive signals
2.4
VHPos
Normal operation
Voltage on HPosF pin as function of ad- HPOS (Sad01)
justment of HPOS register
00000000b
11111111b
3.85 4.0 4.15 V
2.60 2.8 3.05 V
Note 35: Current sunk by the pin if the external voltage is higher than one the circuit tries to force.
Note 36: The threshold is equal to actual VRefO.
Note 37: In the regions of VCC where the device’s operation is disabled, the H-drive, V-drive and B+-drive signals on
HOut, VOut and BOut pins, resp., are inhibited, the I2C Bus does not accept any data.
16/45