TNY263-268
Parameter
OUTPUT
ON-State
Resistance
OFF-State Drain
Leakage Current
Breakdown
Voltage
Rise Time
Fall Time
Drain Supply
Voltage
Output EN/UV
Delay
Output Disable
Setup Time
Auto-Restart
ON-Time
Auto-Restart
Duty Cycle
Symbol
RDS(ON)
IDSS
BVDSS
tR
tF
tEN/UV
tDST
tAR
DCAR
Conditions
SOURCE = 0 V; TJ = -40 to 125 °C
See Figure 18
(Unless Otherwise Specified)
TNY263
ID = 21 mA
TJ = 25 °C
TJ = 100 °C
TNY264
ID = 25 mA
TJ = 25 °C
TJ = 100 °C
TNY265
ID = 28 mA
TJ = 25 °C
TJ = 100 °C
TNY266
ID = 35 mA
TJ = 25 °C
TJ = 100 °C
TNY267
ID = 45 mA
TJ = 25 °C
TJ = 100 °C
TNY268
ID = 55 mA
TJ = 25 °C
TJ = 100 °C
VBP = 6.2 V,
VEN/UV = 0 V,
VDS = 560 V,
TJ = 125 °C
TNY263-266
TNY267-268
VBP = 6.2 V, VEN/UV = 0 V,
See Note H, TJ = 25 °C
Measured in a Typical Flyback
Converter Application
See Figure 20
TJ = 25 °C
See Note I
Min
700
50
Typ
33
50
28
42
19
29
14
21
7.8
11.7
5.2
7.8
50
50
0.5
50
5.6
Max Units
38
57
32
48
22
33
Ω
16
24
9.0
13.5
6.0
9.0
50
µA
100
V
ns
ns
V
10
µs
µs
ms
%
15 G
4/05