WM8804
REGISTER BIT
ADDRESS
R30
0
PWRDN
1Eh
1
LABEL
PLLPD
SPDIFRXPD
2
SPDIFTXPD
3
OSCPD
4
AIFPD
5
TRIOP
DEFAULT
Production Data
DESCRIPTION
1
PLL Powerdown
0 = PLL enabled
1 = PLL disabled
1
S/PDIF Receiver Powerdown
0 = S/PDIF receiver enabled
1 = S/PDIF receiver disabled
1
S/PDIF Transmitter Powerdown
0 = S/PDIF transmitter enabled
1 = S/PDIF transmitter disabled
0
Oscillator Power down
0 = Power Up
1 = Power Down
0
Digital Audio Interface Power down
0 = Power Up
1 = Power Down
0
Tri-state all Outputs
0 = Outputs not tri-stated
1 = Outputs tri-stated
w
PD, Rev 4.5, March 2009
62