WME128K8-XXX
ABSOLUTE MAXIMUM RATINGS
Parameter
Operating Temperature
Storage Temperature
Signal Voltage Relative to GND
Voltage on OE# and A9
Symbol
Unit
TA
-55 to +125
°C
TSTG
-65 to +150
°C
VG
-0.6 to + 6.25
V
-0.6 to +13.5
V
NOTE:
Stresses above those listed under "Absolute Maximum Ratings" may cause permanent damage to
the device. This is a stress rating only and functional operation of the device at these or any other
conditions above those indicated in the operational sections of this specication is not implied.
Exposure to absolute maximum rating conditions for extended periods may affect device reliability.
RECOMMENDED OPERATING CONDITIONS
Parameter
Supply Voltage
Input High Voltage
Input Low Voltage
Operating Temp. (Mil.)
Operating Temp. (Ind.)
Symbol
VCC
VIH
VIL
TA
TA
Min
Max
Unit
4.5
5.5
V
2.0 VCC + 0.3
V
-0.5
+0.8
V
-55
+125
°C
-40
+85
°C
TRUTH TABLE
CS#
OE#
WE#
H
X
X
L
L
H
L
H
L
X
H
X
X
X
H
X
L
X
Mode
Standby
Read
Write
Out Disable
Write
Inhibit
Data I/O
High Z
Data Out
Data In
High Z/Data Out
CAPACITANCE
TA = +25°C
Parameter
Symbol
Conditions
Input Capacitance
Output Capacitance
CIN
COUT
VIN = 0 V, f = 1MHz
VI/O = 0 V, f = 1MHz
This parameter is guaranteed by design but not tested.
Max Unit
20 pF
20 pF
Parameter
Input Leakage Current
Output Leakage Current
Operating Supply Current
Standby Current
Output Low Voltage
Output High Voltage
NOTE: DC test conditions: VIH = VCC -0.3V, VIL = 0.3V
Symbol
ILI
ILO
ICC
ISB
VOL
VOH
DC CHARACTERISTICS
VCC = 5.0V, VSS = 0V, -55°C TA +125°C
Conditions
VCC = 5.5, VIN = GND to VCC
CS# = VIH, OE# = VIH, VOUT = GND to VCC
CS# = VIL, OE# = VIH, f = 5MHz, VCC = 5.5
CS# = VIH, OE# = VIH, f = 5MHz, VCC = 5.5
IOL = 2.1mA, VCC = 4.5V
IOH = -400μA, VCC = 4.5V
Min
Max
Unit
10
μA
10
μA
80
mA
0.625
mA
0.45
V
2.4
V
FIGURE 2 – AC TEST CIRCUIT
IOL
Current Source
D.U.T
Ceff = 50 pf
Vz ~~ 1.5V
Bipolar Supply
IOH
Current Source
AC TEST CONDITIONS
Parameter
Typ
Unit
Input Pulse Levels
VIL = 0, VIH = 3.0
V
Input Rise and Fall
5
ns
Input and Output Reference Level
1.5
V
Output Timing Reference Level
1.5
V
NOTES:
VZ is programmable from -2V to +7V.
IOL & IOH programmable from 0 to 16mA.
Tester Impedance Z0 = 75Ω.
VZ is typically the midpoint of VOH and VOL.
IOL & IOH are adjusted to simulate a typical resistive load circuit.
ATE tester includes jig capacitance.
Microsemi Corporation reserves the right to change products or specications without notice.
July 2011 © 2011 Microsemi Corporation. All rights reserved.
2
Rev. 7
Microsemi Corporation • (602) 437-1520 • www.microsemi.com
Share Link: GO URL

All Rights Reserved © qdatasheet.com  [ Privacy Policy ] [ Contact Us ]