4.3.6 Receive Interface with N+1 Redundancy
For N+1 redundancy, the receivers on the primary cards should be programmed for internal impedance. The
receivers on the backup card should be programmed for "High" impedance mode. To swap the primary card,
set the backup card to internal impedance, then the primary card to "High" impedance. See Figure 39 for a
simplified block diagram of the receive section for a N+1 redundancy scheme.
FIGURE 39. SIMPLIFIED BLOCK DIAGRAM OF THE RECEIVE INTERFACE FOR N+1 REDUNDANCY
Backplane Interface
Primary Card
Internal
Impedence
Primary Card
XRT83L314
Rx
XRT83L314
Internal
Impedence
Primary Card
Rx
XRT83L314
Internal
Impedence
Backup Card
Rx
XRT83L314
Rx
"High"
Impedence
Line Interface Card
1:1
1:1
1:1
T1/E1 Line
T1/E1 Line
T1/E1 Line